Ladder Length Calculator: What Size Extension Ladder to Buy
Enter the height of your roof edge or gutter. Get the ladder length needed at the safe 4-to-1 angle, how far out to set the foot and the smallest extension ladder that reaches. Feet or metres.
Worked out in this browser. Nothing is uploaded or sent to a server.
The tool failed to load. Please reload the page.
Report a problem
Nothing is sent until you press Send.
When to use this
- You are buying or renting an extension ladder to clean gutters or get onto a roof.
- You want to know how far from the wall to put the foot of the ladder.
- You want to check whether the ladder you already have is long enough.
How to use
- Choose feet or metres and say whether you will climb onto the roof or work from the ladder.
- Measure the height from the ground to where the top of the ladder will rest, such as the gutter.
- Press Find the ladder length and read the length, the foot distance and the ladder size to buy.
Examples
- Climbing onto a roof with a 12 ft eave: The rails must reach 12 + 3 = 15 ft high. At the 4-to-1 angle a ladder rises 0.968 ft per foot, so it needs 15 / 0.968 = 15 ft 6 in of usable length. A 16 ft ladder gives only 13 ft after its 3 ft overlap, so buy a 20 ft ladder (17 ft usable). Set the foot about 3 ft 1 in out from the wall.
- Climbing onto a roof with a 20 ft eave: The rails must reach 23 ft high. 23 / 0.968 = 23.75 ft, so you need 23 ft 10 in of usable length. A 24 ft ladder gives 21 ft, a 28 ft ladder gives 25 ft, so buy 28 ft. Set the foot about 5 ft 2 in out.
How it works
Height to reach = roof edge height + 3 ft (roof access) or the support height. At the 4-to-1 angle a ladder rises sqrt(1 - 1/16) = 0.968 of its length, so length = height / 0.968, and the foot sits a quarter of the length to the support out from the wall (about 75.5 degrees). Each extension ladder size is reduced by its minimum overlap and the smallest one that is long enough is shown.
Checked against:
- OSHA 29 CFR 1926.1053(b)(5)(i): horizontal distance about one-quarter of the working length.
- OSHA 29 CFR 1926.1053(b)(1): side rails at least 3 ft above the upper landing surface.
- Cal/OSHA portable ladders eTool (inspecting): minimum overlap of two-section extension ladders (3 ft up to 32 ft, 4 ft over 32 up to 36 ft, 5 ft over 36 up to 48 ft).
- OSHA 29 CFR 1910.333(c)(3): unqualified people keep at least 10 ft from overhead power lines (up to 50 kV); OSHA 29 CFR 1926.1053(b)(12): non-conductive side rails near exposed energized equipment.
Understanding the result
OSHA's rule for a leaning ladder is that the foot sits about one quarter of the working length out from the top support (the 4-to-1 rule). The ladder then stands at about 75.5 degrees and reaches 0.968 of its length in height, so the length needed is the height divided by 0.968. To climb onto a roof, OSHA requires the side rails to go at least 3 ft above the roof edge, so 3 ft is added to the height first. Extension ladders are sold by the total length of both sections, but the sections must overlap: 3 ft on ladders up to 32 ft, more on longer ones. The tool takes the overlap off each common size and picks the smallest that is long enough.
Assumptions this tool makes
- Ladder angle: the horizontal distance from the top support to the foot is about one quarter of the working length. Source: OSHA 29 CFR 1926.1053(b)(5)(i).
- Roof access: the side rails extend at least 3 ft above the upper landing. The tool counts 3 ft of height above the edge, which is the cautious reading. Source: OSHA 29 CFR 1926.1053(b)(1).
- Minimum overlap of two-section extension ladders: 3 ft up to 32 ft, 4 ft over 32 up to 36 ft, 5 ft over 36 up to 48 ft (Cal/OSHA portable ladders eTool; the cautious whole-foot values). Your ladder's label may give a different maximum working length; use the label if it is shorter.
Limitations
- It covers straight and extension ladders leaning on a wall, not stepladders, A-frame or telescoping ladders. Check the label of those for their reach.
- Reaching higher than the ladder is not covered. Do not stand above the highest standing rung marked on your ladder.
- Soft or sloping ground, wind, overhead power lines and the ladder's load rating all matter for safety. The tool only gives a length.
- Heights over 36 ft are not covered. Use scaffolding or a professional.
FAQ
What size ladder do I need for a 12 ft roof?
To climb onto it, the ladder must reach 15 ft high (3 ft above the edge), which takes about 15 ft 6 in of ladder at the safe angle. After the overlap, a 20 ft extension ladder is the smallest common size that does it.
What is the 4-to-1 ladder rule?
For every 4 ft of ladder up to the support, set the foot 1 ft out from the wall. OSHA describes it as a horizontal distance of about one quarter of the working length. The ladder then stands at about 75 degrees.
Why is a 24 ft extension ladder not 24 ft long when extended?
The two sections must overlap to be strong enough. On ladders up to 32 ft the minimum overlap is 3 ft, so a 24 ft ladder reaches about 21 ft along its rails, and less in height because it leans.
How far should a ladder go above the roof?
At least 3 ft above the roof edge, so you have something to hold on to as you step on and off. OSHA requires this when a ladder is used to reach an upper level.